Fittings This Product is no longer available through Houseneeds.com. Inadequate gas pressure or flow. Privacy&Security| Takagi T-H3S-DV-LP Indoor High Efficiency Condensing Tankless Water Heater Liquid Propane Retail : $1,942.00 $1,163.50 You save: $778.50 (40%) Add to Cart Takagi T-H3-DV-NG 199000 BTU Direct Vent Indoor Whole House Tankless Water Heater With Natural Gas Retail : $2,158.00 $1,472.84 You save: $685.16 (32%) Add to Cart We're having difficulty searching. Make sure that there is gas supply to the unit. 5. Brand: Takagi. If you have searched for a part and can not find it - make sure you have contacted Takagi Water Heating directly to obtain an exact part number. Please call us toll free and we can help you find it. Gas valve failure. Help others learn more about this product by uploading a video! RINNAI TANKLESS - Prices have dropped and there are decent deals to be had now! |Manufacturer Part #100076259, To see local availability for this item, please, Brand Model Compatibility: T-K3 Tankless Water Heater, Copyright 2023 Something went wrong. The burner and fan are cycling on and off out of sequence. |Manufacturer Part #EKK1L, Copyright Takagi TK3 code 510 - YouTube This video was uploaded from an Android phone. Storage Tanks If all else fails try rebooting the system by unplugging it and waiting 2 minutes before plugging it back it. When directly purchasing a service part, the buyer is responsible for its safe installation and repair, and cannot holdTakagi Water Heating or Houseneeds.com liable for any improper use or installation of that service part. Please see below for important warranty information. If it does not, check for power to the unit or blown fuses. Thermostats/Controls/ Takagi T-K3 Installation Manual And Owner's Manual 48 pages Summary of Contents for Takagi T-K3 Page 1 CONFIDENTIAL T-K3 Servi c e Manual Ver. Replace the thermistor if you dont see a loose or disconnected wire. Exclusive Water Savings technology conserving up to 1, 100 gallons per year 157, 000 BTU (gas consumed per hour) Exclusive Hot Start Programming minimizes cold water burst by staying in. Free shipping on orders over $99 . All rights reserved. You should receive most shipments within 2 to 10 business days. So expect these special order parts to take an extra 2 or 3 days. Browse by Catagory #1 My takagi tk3 is about 11 years old and until this past winter worked great. C0010475-6A89-419F-B84B-E1AF7ADAF049.jpeg. You must log in or register to reply here. Find many great new & used options and get the best deals for Takagi 100076259 Ekk1l0 Computer Board for T-k3 Make US an OFFER at the best online prices at eBay! so the heat exchanger is probably heavily coated with un-removeable scale. Please use a different way to share. It has either been discontinued, made obsolete, or is no longer available for sale. This Takagi 100076279 T-K3-OS Control Board is a genuine OEM repair part. This past winter when temps were below about 40 degrees it wouldn't produce hot water consistently. Watch out: some errors are signaling a dangerous condition! SKU: 100076279. Refer to your local plumbing inspector or manufacturer for more details. Please try again or, For use in tankless water heaters TK3, TK3-PRO, When it comes to replacement parts and accessories, we have you covered with our wide inventory to meet your need, Factory authorized genuine replacement part. Refer to your local plumbing inspector or manufacturer for more details. Full content visible, double tap to read brief content. Replace the thermistor if you dont see a loose or disconnected wire. Recirculation pump ready kit ready For use outdoors with freeze protection up to -30 degrees $953.00 $49.74 Check Price Now The 'OUT' dipswitch on the computer board should be switched to its 'ON' (up) position (Do not adjust the bank of dipswitches above the LED's). Browse Ferguson's job categories, organized by industry, to find professional-grade equipment, tools and parts for a wide range of projects. Ferguson Enterprises, LLC. Please select another product. Takagi service assistance available to qualified service technicians only via A.O. Scuttlebutt has it that the newer Takagi units aren't as rugged as the older ones. If your systems doesnt have an LCD or remote controller Takagi has installed a red LED that will flash the corresponding error codes. Gas solenoid valve failure. Check wire connections and if no loose wire, replace the AFR rod. TakagiWater Heating strongly recommends the use of a qualified service technician for installation or repair of any gas or electric water heater. This past winter when temps were below about 40 degrees it wouldnt produce hot water consistently. Plumbing Service and repairs on these heaters must be by a qualified service professional. This video was uploaded from an Android phone. Takagi EKK1L Control Board For T-K3 Dedicated to protecting the environment and making the world a safer place to live for families, we make it our mission to produce only the highest quality, most eco-friendly and innovative tankless products possible in hopes to help relieve global warming. Plumbing Supplies. |Item #7276563 These parts are special order and will take longer to process than normal repair part orders. The LED will turn off and the unit should be ready to fire. Check the thermistor and its wires at the water inlet. Amazon has encountered an error. Free Shipping Policy excludes LTL Truck Deliveries and just a few oversized products. Please try again or, Select a Store for Accurate Local Pricing. If you still can not find the part - we can special order most parts thatTakagi Water Heating provides. No modifications were made to the replacement product. Check your Takagi error codes below as there could be a risk of fire, explosion, carbon monoxide poisoning, or even a potential scalding hazard. We have hundreds of locations nationwide, ready to meet your needs. The T-K3 has Easy-Link capability, allowing owners to connect up to four units without the use of a controller unit. Please be sure to provide us with a valid postal address if it's different than the UPS address. Water Heaters Computer Board Th2s Old# Ekh7w. You are using an out of date browser. Abnormal combustion. Part #S100076259 | Item #7276563 | Manufacturer Part #100076259 $ 343.00 EACH. Check for condensate accumulation, blocked or missing condensate drain, condensate leaks. Model T-K3 and T-K3-Pro Suitable for potable water heating and space heating FEATURING ENDLESS HOT WATER ON DEMAND USAGE COMPACT, SPACE SAVING ENERGY CONSERVATION COMPUTERIZED SAFETY NO PILOT LIGHT EASY LINK SYSTEM WARNING This product must be installed and serviced by a licensed plumber, a licensed gas fitter, or a professional Watch out: this is an unsafe condition risking CO hazards. Login for Price. Pex/Radiant If any particular ad is your REASON for blocking ads, please let us know. imagine how well a 5-year old laptop computer works.setting temperature to 140 degrees might be the basic problem:read following resource: http://waterheatertimer.org/troubleshoot-rheem-tankless-water-heater.html#temperature i doubt this takagi computer unit was maintained as shown in product manual, and that heat exchanger was not delimed each Ignition failure; the burners do not light. Check for debris clogging the gas burner or for a failed or blocked fan. HVAC TracPipe CounterStrike Flexible Gas Piping, << Previous in Takagi Parts & Accessories, Powered by Network Solutions Online Store. Takagi T-H3M-DV-N Condensing Direct Vent Tankless Water Heater, Natural Gas 42 5 offers from $949.95 Product Description The Takagi TK-TV10 Direct Vent Conversion Kit converts the Takagi T-K3 (Natural Gas or Propane model) from a regular vent system (intake air from building) to a sealed combustion system (intake air from outdoors). Click Here for more info, - LOC 9120 - Part is also referenced as part number 100076259, This part works for - Takagi T-K3 and T-K3PRO Water Heaters, Takagi Tankless Water Heater - Computer Board for T-K3 and T-K3PRO - LOC 9120 - EKK1L - 320273-296 - Non-returnable, Part is also referenced as part number 100076259. Alternatively for Easy-Link System units, The 7Seg LED of the individual unit with the error in question displays the whole 3digit error code. It looks like you're using an ad blocker. Get Started to create a new Ferguson account. Rating: (0) Q&A: (0) Hover image to zoom. LEAD LAW WARNING: In accordance with the US Federal or other States laws It is illegal to install products that are not lead free certified in potable water systems anticipated for human consumption. Answered in 30 minutes by: HVAC Technician: HVAC Guru. Takagi error codes may be displayed in different locations on some units. View cart for details. We're having difficulty searching. View Cart. If there is a problem with the installation or the unit, it will display a numerical error code on the Remote Controller (if installed), or on the 7Seg LED on the computer board (510 (TD2). Water Boosters Water Heater Parts. Consult the chart for the cause of each error code. Takagi requires the use of its part No. See your water heater manual or troubleshooting manual for your specific water heater model for expanded detail about the meaning and the corrective steps for each of these error codes. Takagi tankless water heaters are equipped with an advanced computer board and self-diagnostic system that allow you to check if a problem occurs inside the unit. The TMRE30 (if installed) displays a 3digit number which signifies which unit has the error, and what the error code is if you have a multi unit system. Takagi Tankless Water Heater - Computer Board for T-K3-OS and T-K3-SP - EKK4N - 320273-316 - Non-returnable - Part also referenced as part number 100076279 - LOC 9193 Product ID TAKEKK4N0000 This Product is no longer available through Houseneeds.com. Before you call us, make sure you have done the following: Make sure you have obtained the exact part number fromTakagi Water Heating If you do not have an exact part number - we will not be able to help you! adidas Originals Classic Superlite Super-No-Show Socks 6 Pairs Men's, Xbox Series S 512GB SSD Console + Watch Dogs: Legion (Email Delivery), ZWILLING TWIN Signature 5.5-inch Prep Knife, Sony Noise-Cancelling True Wireless Bluetooth Earbuds - WF-1000XM4 - Black, Lenovo IdeaPad 3 14" FHD Laptop Intel Core i5-1135G7 8GB RAM 512GB SSD, adidas Originals Geodiver Primeblue Shoes Men's, Lenovo IdeaPad 3 14" FHD Laptop Intel Core i7-1165G7 8GB RAM 512GB SSD, Apple HomePod mini Wi-Fi Bluetooth Wireless Siri Smart Speaker Excellent, Elite Trainer Box ETB Crown Zenith Pokemon TCG SEALED PRESALE SHIPS 1/20, PlayStation 5 Console God of War Ragnarok Bundle, 11 PCS Resistance Band Set Yoga Pilates Abs Exercise Fitness Tube Workout Bands, AKG N5005 Reference In-ear Headphones with Customizable Sound, Black, Apple iPhone 13 Pro Max, A2484, 128GB, Unlocked, Excellent Condition (Free Ship), 6.5 x 9.25 Padded Bubble Mailer Color Logo, adidas Originals Swift Run 22 Shoes Men's, Intel Core i5-13600K Unlocked Desktop Processor - 14 Core (6E+8P) & 20 Threads, adidas Ultraboost 22 COLD.RDY 2.0 Running Shoes Men's. The unit is not flashing any error codes. I got a 991 fault on my Takagi H2 water heater. Verified. Bs_aggie, what was the outcome? The support guy said usually when you see this the control board is also bad and I would need to replace both. Sign up to receive email about product launches, events, deals & more! Check them out. Service Manual Communication Error in Easy-Link or Multi-Link System. Look for a blocked flue or chimney (or downdrafts in the chimney) or a problem with the draft inducer fan. As the weather warmed the problem disappeared until a couple of weeks ago when the problem resurfaced. as if any computer will last 20 We might be able to do something about it. For a better experience, please enable JavaScript in your browser before proceeding. Check for a bad igniter, flame sensor, gas valve. since yearly deliming will not fully remove scale on tankless units, the tankless computer is designed to sprial downward in efficiency despite glossy brochures that promise endless and effortless hot water for 20 years . We may miss your phone call as we are currently experiencinghigher than normal call volumes. JavaScript is disabled. Full content visible, double tap to read brief content. Discover more than 100,000 products online at Ferguson today! 4. Compare. Login for Price. Improper gas combustion. Expansion Tanks Part #S100076259 Remote control not communicating with the water heater, check remote batteries, check remote sensor wiring, remote control access line of sight. Terms of Sale| Do Not Sell My Personal Information| Takagi Ekj06, Computer Circuit Board For T-Kjr(320273-258) (100076222). Takagi Water Heater repair parts ship via Fedex or USPS. My takagi tk3 is about 11 years old and until this past winter worked great. Help others learn more about this product by uploading a video. Log In / Create Account. NEW TAKAGI COMPUTER MAIN BOARD for T-KJR2U 110U TANKLESS WATER HEATER 319143-469. Rinnai Tankless Error Code 11 Troubleshooting, The Importance of Insulating Hot Water Pipes, Wrong dip switch setting Red LED / Computer Board Fault, Inlet Thermistor / Output Thermistor / Air-fuel ratio rod failure, Warning for 991 error code / Abnormal Combustion, Abnormal Gas Valves / Abnormal Solenoid Gas Valve / False Flame Detection, Wrong dip switch setting, 110 (T KJr2), 310 (TK4) Remote, T-D2, T-H2-OS, T-H3-DV/OS, T-H3J-DV/OS, T-H3S-DV/OS, T-M32, T-M50, Wrong dip switch setting, possibly LP gas set when the fuel is Natural gas, or vice versa. MFG # 0. http://www.youtube.com/FergusonEnterprises, https://www.houzz.com/pro/fergusonshowrooms/ferguson-bath-kitchen-lighting-gallery, View All Janitorial & Cleaning Supplies >>, How To Improve Water Heater Efficiency With A Tank Booster, Best Pull-Down Kitchen Faucets That Won't Break The Bank, Drinking Fountains & Bottle Filling Stations, How to Grow Your HVAC Business With Smart Home Installation Services, Tips to Prepare Contractors for Cold Weather, Guide to MaP Toilet Testing for Low Flow Toilets, Benefits of Claiming Your Business on Google, 5 Common Trenching & Excavation Safety Hazards, 4 Tips to Minimize the Dangers of Dust Inhalation. Flow Sensor Failure (Easy-Link or Multi-Link System Only). Find all Takagi service manuals and troubleshooting . Upload your video. Terms of Sale| 888.882.5244 www.takagi.com TK-TV10 Direct Vent Converstion Kit (optional) TM-RE30 Temperature Remote Control (optional) . TakagiWater Heater repair parts ship via Fedex or USPS. The outdoor vent cap must be used when unit is installed outdoor. IT DOES CYCLE BUT WILL NOT IGNITE; NEEDS Control Unit (Circuit Board). Please try again later. The T-K3 model is one of Takagi's most versatile and powerful residential tankless water heaters. CAPrivacyRights| It has either been discontinued, made obsolete, or is no longer available for sale. HVAC Guru, HVAC TECH. Specs Condition: Brand New Brand: Takagi Item ID: 100076279 Warranty: Must be installed by a licensed technician. Takagi tankless water heater parts Takagi Tankless Water Heater Control board PCB for T-KJR2-IN/OS - EK420 - 319143-164 - Part is also referenced as part number 100074348 - LOC 9315 Takagi Tankless Water Heater - Fan Motor for T-KJR-2-IN/OS - EX02E - 319143-347 - Non-returnable - Part is also referenced as part number 100074531 - LOC 9165 Takagi Tankless Water Heater - Flame Rod for T-KJR2-IN . Takagi OEM Control Boards Takagi OEM Control Boards Get genuine Takagi factory OEM Control Boards for your Takagi unit. Output thermistor failure. Do Not Sell My Personal Information| . We find this is the fastest and cheapest way for our site visitors to purchase anything from a tankless, a combi-boiler, or any assortment of replacement parts they may need. You should receive most shipments within 2 to 10 business days. All units are put into a self diagnostic state for all Takagi error codes, this is for your safety and convenience when trouble shooting. I'm not sure how susceptible the TK3 is to power surges (probably fairly robust), but induced voltage spikes from lighting strikes or extreme switching noise on power lines can do-in just about anything. Check for a blown fuse on the circuit board. Compare. Save time shopping for the products you need for your next job. Some parts of this page is temporarily unavailable. Water Filters 2023 controlled by onboard solid state printed circuit board monitoring incoming and outgoing temperatures with factory installed thermistors . With superior services, our premiere loyalty program and cutting-edge technology solutions, we provide you with what you need in order to set your business apart from others. Heat Exchanger Tk3 Ekk1x. TakagiWater Heater repair parts ship via Fedex or USPS. Please select another product. Thanks for any feedback you can offer! TAKAGI 100074342 T-K4 CONTROL BOARD. Furnaces I talked with takagi tech support and they explained how to pull codes from memory and it was flashing 611 which is a fan motor error. Possible: Inlet filter clogged, water flow problem. Input / Inlet thermistor failure. Takagi T-KJR2-IN-NG does not demand electric power to provide you warm water. The basic heat exchanger and other components are usually good for 20+ years in a residential application. It seems to happen at higher flow rates, for example a single sink faucet is fine but 2 faucets or the shower or tub cause it to start cycling. Free Shipping Policy excludes LTL Truck Deliveries and just a few oversized products. TheTakagi phone number is as follows:1-888-882-5244, PDF Takagi TK3-03 TK3-SP Manual - Discontinued, 2000 - 2022 Houseneeds, Inc. 131 S Main Street Suite 1, Barre Vermont 05641 (802) 583-2726, Condensing Boiler 3" Concentric Termination Kit, View all Takagi Gas Tankless Water Heaters, View all Plumbing PEX Tubing and Accessories, View all Expansion Tanks for Domestic Hot Water Systems. I have a Takagi T-K1s, at least 12 to 15 years old by now, has been working well until recently it started not working intermittently. . Part # 100074380. Takagi's technical help line is fairly DIY-friendly and will talk homeowners through the diagnostics without an hourly charge: 888.882.5244 If you'd like to support the site, please allow ads. Most small, light weight parts on this page ship via Post Office. Get Started to create a new Ferguson account. Also check for loose wire connections. Push the reset button. Category: HVAC. We have hundreds of locations nationwide, ready to meet your needs. All rights reserved. Check the thermistor and its wires on the heat exchanger. It is brand new in the original Takagi factory packaging and is guaranteed to fit and function properly. (110 (TKJr2), 310 (TK4)) use this method to display the source of the problem.